Jacuzzi Portable Generator SteamPro User Manual

TM  
STEAMPRO  
Steam Generator  
Installation and Operating Manual  
o
SteamPr  
 
Contents  
Installation of Steam Generator  
Specifications ______________________________________________________________________________ 1  
How to Select Generator Size and Electrical Requirements ___________________________________________ 2  
Locating the Steam Generator _________________________________________________________________ 3  
Room Construction and Ventilation _____________________________________________________________ 3  
Plumbing Instructions and Cautionary Notes on Installation __________________________________________ 4  
Plumbing Diagram___________________________________________________________________________ 5  
Steam Head Installation for Various Wall Surfaces _______________________________________________ 6, 7  
Automatic DrainValve Installation (Optional) ______________________________________________________ 8  
Steam Controls—Operating Instructions and Installation Methods  
Steam Control Options _______________________________________________________________________ 9  
Steam Control by 30 Minute ON/OFF Control ____________________________________________________ 10  
Rough-In and Installation of Temperature Controls _____________________________________________ 11, 12  
Operating Instructions  
Steam Control by 30 MinuteTemperature Control _________________________________________________ 13  
Steam Control by DigitalTime andTemperature Control ____________________________________________ 14  
Service ___________________________________________________________________________________ 15  
Troubleshooting __________________________________________________________________________ 16, 17  
Wiring Diagram _____________________________________________________________________________ 18  
Warranty _______________________________________________________________________________ 19, 20  
GENERAL DESCRIPTION  
SteamPro™ steam generators from Jacuzzi Whirlpool Bath are designed for compact size and easy installation and  
provide full, high volume steam for luxurious steam bathing.The accessories and control options have been designer  
for easy plug-in installation and function with all sizes of SteamPro™ generators. For residential use only.  
29½"  
16½"  
6¼"  
29½" FOR PLUMBING  
CLEARANCE WITH  
AUTOMATIC DRAIN  
VALVE.  
13"  
(23" WITH MANUAL VALVE  
IF VALVE IS INSTALLED  
HORIZONTALLY. 21"  
WITH MANUAL VALVE IF  
o
ELBOW IS ADDED TO  
INSTALL VALVE  
VERICALLY WITH DRAIN  
LINE.)  
SteamPr  
SPECIFICATIONS  
AVAILABLE  
SIZES  
MODEL  
NUMBER  
DIMENSIONS  
LxWxH  
PACKAGED  
SHIP WEIGHT  
5kW  
7kW  
10kW  
S064000  
S062000  
S060000  
16½”x 6¼”x 13”  
16½”x 6¼”x 13”  
16½”x 6¼”x 13”  
27 lbs.  
28 lbs.  
28 lbs.  
1
 
INSTALLATION  
Specifications and Sizing of the Steam Generator for the Room  
Single-Phase Electrical Service  
Required  
Generator Power  
Rating at Voltage  
Size of Enclosure  
(cubic feet)  
240 VAC 30 AMP 3 WIRE (#10)  
208 VAC 30 AMP 3 WIRE (#10)  
240 VAC 40 AMP 3 WIRE (#8)  
208 VAC 40 AMP 3 WIRE (#8)  
240 VAC 60 AMP 3 WIRE (#6)  
208 VAC 60 AMP 3 WIRE (#6)  
5.0 kW@240  
3.75 kW@208  
7.0 kW@240  
5.25 kW@208  
10.0 kW@240  
7.5 kW@208  
60-110  
60-80  
STEAMPRO  
240/5  
S064000  
110-220  
80-150  
220-400  
150-230  
STEAMPRO  
240/7  
S062000  
STEAMPRO  
240/10  
S060000  
How to Select Generator Size  
Step 1. Determine cubic footage of steam enclosure: multiply LENGTH inches x WIDTH inches x HEIGHT inches  
to find cubic inches. Divide cubic inches by 1728 to determine cubic feet.  
Step 2. Find steam enclosure size within the ranges shown on the chart for the supply voltage  
(240 VAC or 208 VAC).  
Step 3. Consider material and climate: If the steam enclosure is constructed of tile or marble or if the steam  
enclosure is against poorly insulated outside walls in a cold climate, select the next higher or highest kW  
size of steam generator available. Natural stone such as marble may reduce the cubic cpacity by as  
much as 50%.  
Electrical Requirements  
All SteamPro generators operate at 208 or 220 to 240 VAC at 50 or 60 Hz. Circuit is to be single phase 3-wire (two  
conductors at line voltage and one ground conductor must be provided). Bond the SteamPro generator with a #8  
minimum gauge solid copper wire from the bonding clamp at the unit to the house electrical panel or approved local  
ground. An approved ground may be an 8 foot long ground rod (3 meter length earth rod), a plate electrode, or other  
acceptable bond. Check your local building code for requirements.  
Caution:Without proper grounding and bonding, a system malfunction may cause fatal shock.  
2
 
INSTALLATION  
Locating the Steam Generator  
The steam generator must be installed upright and level. The steam generator must be located within a 25 foot  
maximum steam line run to the steam head AND within the 25 foot control wire length to any controls. It may stand  
attached to a horizontal base or to a wall. For wall mounting, use keyholeslots on a cabinet back to slip over screw  
heads and install a wood cleat or shelf to the wall at the bottom of the unit to help support the bottom. Add a cleat at  
the top to keep the unit in place.  
Install the steam generator indoors only and in a dry location that will not be subject to freezing. If exposure to  
freezing can not be avoided (e.g., seasonal-use homes), the optional automatic tank drain down valve must be  
installed. Turn off the power and water supply to the unit if it will not be used for an extended period of time.  
Room Construction and Ventilation: Important  
The room in which the steam generator is to be located must be constructed of materials that can withstand excessive  
amounts of moisture and condensation. Large amounts of steam can be released into the room when the enclosure  
door is opened. Providing natural or forced ventilation of the room will help maintain comfort and minimize moisture  
damage to the building. Jacuzzi Whirlpool Bath is not responsible for damage resulting from excessive moisture.  
Consult an architect or engineer for aid in designing your room structure.  
HEATED ATTIC  
STEAM  
ENCLOSURE  
INSIDE VANITY  
OR CABINET  
ADJOINING  
CLOSET  
BASEMENT  
3
 
INSTALLATION  
Plumbing Instructions and Cautionary Notes on Installation  
Minerals in the water or poor water quality can shorten the life of the steam generator or cause erratic operation if  
the tank is not drained regularly. Drain the tank frequently. Jacuzzi Whirlpool Bath also strongly recommends  
purchasing and installing the optional drain down valve. See the important note below. The tank will be drained  
automatically after each use after the water temperature lowers. Water filters and other conditioners are strongly  
recommended if the water is of poor quality.  
Guard against possible contact with hot steam pipes and other plumbing.  
Maximum run of the steam pipe is 25 feet. The steam pipe should be insulated. This will reduce condensation in  
the steam line and will increase efficiency. Use only copper and brass pipe and fittings, 1/2 inch minimum.  
Install a water supply shutoff valve where it is easily accessible.  
The water supply pipe should be attached to cold supply. Do not use a saddle or piercing type connection for the  
steam unit water supply.  
Apply thread compound sparingly to fitting threads such that excess compound does not dislodge and restrict the  
copper pipes or filter screen. Flush lines before making connections to the generator.  
When tightening or loosening fittings, always use a backup wrench to hold the adjacent fitting.  
Caution: Do not install any valves or create restrictions in the steam line. Do not construct any dips or valleys  
in the steam line as condensation will accumulate in these and block the pipe with water. Pitch the steam line  
such that condensation will run to the steam generator (preferable) or to the steam head.  
Important Note About Tank Drain Selection:  
Jacuzzi Whirlpool Bath strongly recommends purchasing and installing the optional Automatic Tank Drain Valve  
for the steam generator. This drain valve prevents standing water from remaining in the tank between uses.  
The Automatic Tank Drain Valve must be installed where the steam generator may be exposed to freezing  
temperatures, e.g., in seasonal-use homes. (Water supply lines and water solenoid valve must not be allowed to  
freeze.) This option prevents standing water from remaining in the tank. The tank will be automatically drained  
through this valve when the water has cooled.  
Read all warranty provisions before selecting a manual drain valve or the automatic drain down option.  
4
 
INSTALLATION  
Plumbing Diagram  
STEAM UNIT TO BE LEVEL AND UPRIGHT SEE  
PAGE 5 FOR SUGGESTED LOCATIONS  
SEE CHART ON  
PAGE 4 FOR  
REQUIRED  
WATER SUPPLY  
WITH SHUT-OFF  
VALVE (3/8 OR 1/2  
INCH COPPER)  
WIRE SIZE.  
TO STEAM HEAD SEE  
PAGES 8 AND 9 FOR STEAM  
HEAD PLUMBING AND  
INSTALLATION FOR VARI-  
OUS WALL SURFACES.  
STEAM PIPE 1/2 INCH  
(MINIMUM SIZE) COPPER.  
25 FOOT TOTAL MAXIMUM  
RUN. DO NOT PLACE ANY  
VALVES OR DIPS IN THIS  
LINE. PIPE INSULATION  
RECOMMENDED  
o
SteamPr  
PRESSURE RELIEF VALVE 3/4 NPT  
(PROVIDED WITH STEAM GENERATOR)  
*SHOWN WITH OPTIONAL  
AUTOMATIC DRAIN VALVE  
(SEE PAGE 10)  
REDUCTION FROM 3/4 NPT TO 1/2 NPT  
PERMITTED  
PRESSURE RELIEF VALVE DRAIN LINE.  
DRAIN LOCATION AND METHOD AS  
REQUIRED BY LOCAL CODES. (TO BE  
1/2 INCH MINIMUM SIZE COPPER)  
TANK DRAIN LINE. INSTALL  
SITE DRAIN OR OTHER  
DRAINAGE METHOD AS  
REQUIRED BY LOCAL  
CODES (WITH AUTOMATIC  
DRAIN OPTION, WATER  
DISCHARGED IS LESS THAN  
14F).  
*TANK DRAIN WITH MANUAL  
VALVE (MANUAL DRAIN VALVE  
IS PROVIDED WITH STEAM  
GENERATOR)  
MANUAL TANK DRAIN VALVE.  
LOCATE IN AN AREA EASILY  
ACCESSIBLE TO ALLOW  
FREQUENT DRAINING.  
NOTE: ALL COPPER PIPE  
SIZES ARE TO BE INDUSTRY  
NOMINAL SIZES. PLUMBING  
AND FITTINGS ARE NOT  
PROVIDED UNLESS NOTED  
OTHERWISE.  
1/2 INCH MINIMUM  
COPPER  
5